more knowledge of scaffolding and aluminum beam description.
Steel scaffolding performance test sliding fastener doing, when applied in the horizontal pipe (fasteners on both sides) to increase the vertical constant load P reaches the specified value, the measured displacement 1 and 2.

P is contained in the pre-loading 1.0kN, it will be adjusted to zero displacement measuring instrument. When P increased to 7.0kN, write down the value of 1; when P increased to 10.0kN, write down the value of 2. Fastening two a circular surface should be tested.
Experimental anti-sabotage: skid resistance tests, no damage to the damaged fastener can be used as performance tests against. At this point the lower fastener support attached a non-slip pad. When P is 25.0kN, the fastener must not damage the parts. test only a circular surface.
Slip Test: Test methods shall comply with the provisions of 5.2.1 of this guide book, preloading P should be 0.2kN. When P increased to 7.0kN, write down the value of 1; when P increased to 10.0kN, write down 2 values.
Fastener tensile performance tests on the sector: the increase in fastener under constant axial tension, measured displacement upge0tp. When preloading P is 1.0kN, it will be adjusted to zero displacement measuring instrument, and then continue loading.
When P increased to 4.0kN, write down the value of . Base compression performance test: to 1.0kN / s speed of uniform loading. When P is 50.0kN, the base may damage. Test against damage: the skid resistance After the test, performance test for anti-sabotage. When P is 17.0kN, the fastener must not damage the parts.
Relevant reports:http://www.iscaffold.org